Specifications
| Working environment | compressed air, gases, gas-air mixtures, saturated steam |
| Gas separator capacity (average), nm3/min. | 25 |
| Working pressure, MPa (kgf/cm2) | 1,0 (10) |
| Operating temperature, °С | from +5 to +200 |
| Height (with storage), mm | 795 |
| Width, mm | 320 |
| Case diameter, mm | 219 |
| Weight, kg | 38 |
Reviews
Samara Stroyfarfor LLC, Samara
Chief Engineer
The HCV 1-06.2 vortex gas dynamic separator was installed in March 2011 in the compressor section after the screw oil-filled compressor (standard equipment without integrated air-cooled dryer) with operating parameters: outlet pressure 7.2 bar, capacity 26.1 nm3/min to the air collectors.
To check the efficiency of the HCV 1-06.2 vortex gas dynamic separator, the following devices were installed on the separator outlet pipeline:
1. Flow meter with functions: accounting for instantaneous flow, pressure and temperature
2. Dew point temperature sensor
Readings of the measurements made:
1. The pressure at the outlet of the separator is 7.2 bar (at the outlet pressure of the compressor is 7.2 bar)
2. Flow rate - 26.1 nm3/min
3. Temperature +34 °C (at compressor outlet temperature +35 °C)
4. Dew point temperature +8 °C
Manufacturer's compressed air quality tests according to GOST 9.010-80 (directional compressed air jet 0.25 nm3/min through a 9 mm diameter nozzle from a distance of 50 mm onto clean filtered paper for 10 minutes - no moisture and oil stains and directional compressed air jet 0.25 nm3/min through a 9 mm diameter nozzle from a distance of 50 mm mm on the surface of the mirror for 3 minutes - a matte coating and spots from drops of moisture and oil were absent).
Based on the results of measurements and tests, it was decided to use vortex gas-dynamic separators of this type on the compressor equipment of Samara Stroyfarfor LLC.
To check the efficiency of the HCV 1-06.2 vortex gas dynamic separator, the following devices were installed on the separator outlet pipeline:
1. Flow meter with functions: accounting for instantaneous flow, pressure and temperature
2. Dew point temperature sensor
Readings of the measurements made:
1. The pressure at the outlet of the separator is 7.2 bar (at the outlet pressure of the compressor is 7.2 bar)
2. Flow rate - 26.1 nm3/min
3. Temperature +34 °C (at compressor outlet temperature +35 °C)
4. Dew point temperature +8 °C
Manufacturer's compressed air quality tests according to GOST 9.010-80 (directional compressed air jet 0.25 nm3/min through a 9 mm diameter nozzle from a distance of 50 mm onto clean filtered paper for 10 minutes - no moisture and oil stains and directional compressed air jet 0.25 nm3/min through a 9 mm diameter nozzle from a distance of 50 mm mm on the surface of the mirror for 3 minutes - a matte coating and spots from drops of moisture and oil were absent).
Based on the results of measurements and tests, it was decided to use vortex gas-dynamic separators of this type on the compressor equipment of Samara Stroyfarfor LLC.